Cylindrical concrete cores lined up on a laboratory bench, one under a compression testing machine.

Testing

Closing the loop: core testing under ASTM C39 and C42

Destructive testing after the print is what converts a claim about your wall into evidence about your wall.

Cores are the only evidence that describes the structure as built rather than as intended. For a printed wall that distinction carries more weight than it does for cast concrete, because the interlayer planes are a product of the process, not the mix.

Orientation is not a detail

A core taken so that the interfaces sit perpendicular to the load axis reports something different from one taken parallel. Both are legitimate. Reporting one without stating which was taken is not.

  • Record extraction location, orientation and height within the wall
  • Record the ambient conditions and layer timing at that location during the print
  • Test to the established parameters rather than an in-house variant
  • Report the interface orientation alongside the strength result

Done properly, a core programme lets you say something specific about your wall to a structural reviewer. Done loosely it produces numbers that invite more questions than they settle.

References

Standards, code provisions and peer-reviewed work this article rests on. Designations are given in full so a reviewer can pull the source themselves.

  1. ASTM C39/C39MStandard

    Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

    ASTM International

  2. ASTM C42/C42MStandard

    Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete

    ASTM International

  3. ICC-ES AC509Standard

    Acceptance Criteria for 3D Automated Construction Technology for 3D Concrete Walls

    ICC Evaluation Service

    The product-side criteria: wall properties, fire resistance and structural testing, plus the quality documentation an evaluation requires.

  4. Le et al. (2012)Peer-reviewed

    Hardened properties of high-performance printing concrete

    T. T. Le, S. A. Austin, S. Lim, R. A. Buswell et al. · 2012 · Cement and Concrete Research, 42(3), 558–566

    Early and still widely cited measurement of how the delay between layers changes hardened bond strength.

Citing a standard is not the same as certifying compliance with it. Nothing here is engineering certification, legal advice or a code approval.

Facing this on a live project?